For decades, firefighters have adapted to changes in building design, construction methods and fire behaviour. However, the pace of change has accelerated dramatically in recent years. Modern lightweight construction, increasingly energy-efficient buildings, evolving ventilation systems and the influence of environmental conditions are all reshaping the risks faced on the fireground. While these developments bring many benefits for building owners and occupants, they can also introduce new and often less predictable hazards for emergency responders.

Understanding how these changes affect firefighting operations is essential. Lessons learned from international research, operational experience and firefighter fatality investigations provide valuable insight into the dangers associated with modern fires and the tactical considerations needed to manage them safely. Ultimately, every innovation in building design or fire safety technology should be viewed through a simple but critical lens: what does this mean to the firefighter?

The UK and many parts of Europe are following design and construction trends, using lightweight timber in residential buildings, that became most popular in the USA over 25 years ago. Therefore a look at North American firefighter injury statistics from fires that occurred during recent periods might serve as some sort of warning to us. According to data from the United States Fire Administration (USFA), during the period 1977 through 2002, there was an average of 115 fire fighter fatalities per year, not including the 343 fire fighters who died at the World Trade Centre on 11 September 2001. Over the same period, there have also been approximately 45,000 non-fatal firefighter injuries annually, occurring at a fire scene. Structural fires pose particular hazards to fire fighters from structural collapse or becoming lost or disoriented and unable to escape before running out of oxygen. For the period 1977 through 2000, the number of fire fighter deaths in structure fires declined 59%; however, the rate of fire fighter deaths (per 100,000 fires) from traumatic injuries during structural firefighting has actually increased over this same time period.

• Although the number of fire fighter deaths in structure fires has declined over the last 20 years, the rate of fire fighter deaths from traumatic injuries during structural firefighting has actually increased over this same time period.

• Structural fires pose particular hazards to fire fighters; fatalities while fighting structural fires typically involve structural collapse, rapid fire progression, and trapped firefighters.

• Assessing the integrity of a burning lightweight building is a complex task, and presents a difficult problem for the fire service in determining when a catastrophic, life threatening event, such as a major collapse, will occur; at present, there are no uniform assessment tools to assist incident commanders and fire fighters in accurately determining when to exit a burning structure before it collapses.

• In only 20% of the NIOSH (USA) investigations of fatalities due to structural firefighting had fire fighters begun an evacuation before the structure collapsed.

• To reduce fire fighter fatalities during structural firefighting, additional efforts must be directed to more effectively use what we have learned through past experience.

• Additional training for incident commanders and firefighters may enhance awareness of the hazards of structural fires and be useful in guiding critical decision making on the fire ground.


Opening doors at the stair in a high-rise can cause you big problems, as can the automatic opening of a smoke shaft or vent (AOV) during a wind driven fire**. As a flow-path is created (air inlet to smoke and heat outlet) the temperatures created by a wind driven fire will increase. As a door or automatic opening vent (AOV), or a smoke shaft opens, the flow-path is initiated. In a wind driven fire these additional openings will intensify the fire development and ‘pull’ fire and heat into the paths of firefighters and escaping occupants, placing firefighters directly in the hot zone of a flow-path. The pressure differentials that can be set-up by AOVs or smoke shafts opening behind firefighters with a developing fire in front of them can be hazardous and all means of placing barriers, such as closed doors, between the fire and the vent outlets should be utilised at all costs.


The hazards associated with flow-path reversal under exterior wind conditions are not solely reserved for high-rise fires. A wind-driven fire can occur at any time and in any building. Know the wind speed and direction when you book on duty and take account of these two critical features in tactical size-up and deployment at every fire as you dismount from the fire engine.

A safe strategy for basement fires has always been –

• A firefighting crew should not descend into a basement fire without wearing BA and taking a charged hose-line of at least 45mm diameter (or one that provides adequate water).

Water supply must be adequate for purpose and augmented immediately.

• A second crew with at least a 45mm diameter (or larger) charged line should be in support as soon as staffing assignments allow.

• The second hose-line can be sited at the top of the stairs to protect the attack teams egress.

• Remember – where hose-lines are taken down stairs into basements, the hose behind you may now be at ceiling height and could be exposed to ceiling fire temperatures.

• Where conditions at the top of the basement stairs suggest any descent by the primary attack team is likely to expose firefighters to untenable conditions, a holding position at the top of the stairs may protect fire from spreading upwards to trap occupants or firefighters undertaking search and rescue on upper floors.

• Do not implement any low level tactical venting actions where firefighters are located above the fire or are descending into a basement.

• At the earliest opportunity, consider alternative and optimum entry points to a basement fire and also consider the viability of an exterior stream to gain some reset of the fire.

• Ongoing communications with interior crews are essential.

• Where communication is lost with firefighting crews in a basement fire, the second team in support should descend into the basement to locate them and a third charged hose-line should be placed at the top of the stairs as cover.

The common thread running through each of these examples is that the fireground continues to evolve, often more quickly than firefighting tactics, training and operational procedures. Lightweight construction, flow-path dynamics, wind-driven fire behaviour and basement fire conditions all demonstrate how rapidly a seemingly manageable incident can escalate into a life-threatening situation for firefighters.

The challenge for today’s fire service is not simply to recognise these hazards, but to understand how they interact and influence tactical decision-making. Situational awareness, continual training, effective communication and a willingness to adapt established practices are essential if firefighters are to operate safely in increasingly complex environments.

As building design and fire behaviour continue to change, the question remains as relevant as ever. Every new construction method, ventilation strategy or operational procedure should be assessed not only for its impact on property and occupants, but also for the firefighters who will one day be called upon to respond. Understanding the answer to that question may ultimately be the difference between a successful intervention and a tragic outcome.

Content published from Euro Firefighter 2 and is written by Paul Grimwood, PhD, FIFireE