Home Firefighting Foam Concentrate PHOS-CHEK 1% AFFF Foam

PHOS-CHEK 1% AFFF Foam

by Greg Preston
PHOS-CHEK 1% AFFF Foam

PHOS-CHEK 1% AFFF Foam supplied by PHOS-CHEK

PHOS-CHEK® 1% aqueous film-forming foam (AFFF) concentrate is a mixture of water, hydrocarbon surfactants, solvents, and C6 fluorosurfactants. The C6-based AFFF is an environmentally responsible, next-generation product for use on Class B hydrocarbon fuels that have low water solubility. This novel formulation demonstrates Perimeter Solutions’ commitment to superior firefighting performance and environmental responsibility.

Pure C6 PHOS-CHEK 1% AFFF is designed for rapid control and knockdown. The product produces a thin aqueous film that minimizes vapor release; a foam blanket that separates the fuel from the air; and continual draining of water from the foam blanket, which provides cooling to the fuel surface.

APPLICATIONS

Phos-Chek 1% AFFF may be used with low expansion foam equipment (nozzles, monitors, foam chambers, etc.), non-aspirating devices (water spray nozzles and standard sprinklers) and medium expansion foam devices to fight fires involving Class B hydrocarbon fuel fires such as crude oil, aviation fuels, diesel, etc. It is not suitable for use on polar solvents or water miscible fuels such as alcohols, ketones, esters, and ethers.

APPROVAL CERTIFICATIONS

UL 162 and EN 1568-3 (Class IB) listed, Foam Liquid Concentrates

STORAGE AND HANDLING

The concentrate should be stored at temperatures between 23 ̊F (-5 ̊C) and 122 ̊F (+50 ̊C), preferably in the original containers, approved bladder tanks, stainless steel, high density polyethylene, fiberglass or epoxy lined tanks. Concentrate piping acceptable materials of construction include stainless steel (either 304 or 316), some plastic piping including fiberglass and PVC, red brass, and black iron as long as the system is completely flooded eliminating the air/foam concentrate/carbon steel interface. Avoid permanent contact with carbon steel, iron, some copper alloys, & aluminum when the piping material and concentrate will be exposed to air. Galvanized piping is not recommended for AFFF piping systems.Foam concentrates are subject to evaporation, which accelerates when the product is exposed to air. Storage tanks should be sealed and fitted with a pressure vacuum vent to prevent free exchange of air.

SHELF LIFE, INSPECTION AND TESTING

The shelf life of any foam concentrate is maximized by proper storage conditions and maintenance. Factors affecting shelf life are wide temperature changes, extreme high or low temperatures, evaporation, dilution, and contamination by foreign materials. Properly stored Phos-Chek AFFF Class B foam concentrates should have no significant loss of firefighting performance for 20+ years. However, the National Fire Protection Association (NFPA) recommends annual testing of all firefighting foams.


PHOS-CHEK

PHOS-CHEK 1% AFFF Foam supplied by PHOS-CHEK

Telephone: +1 (800) 682-3626  Email: Click to email Website: Click to visit website

To receive more details please complete the request form below.